nice 2000 B Infant Radiant Warmer

0.00৳
0.00৳

Phone

+1 (212) 555-7890

Secure Payment

100% Secure Online Payment

Free Delivery

Free Delivery & Installation

Dedicated Support

Dedicated Online & Offline Support

The nice 2000 B Infant Radiant Warmer is an advanced neonatal warming system designed to provide safe and effective thermal care for newborns in NICUs, delivery rooms, and neonatal care units. Featuring microcontroller-based temperature control, servo skin mode, quartz infrared heating, comprehensive safety alarms, and uniform heat distribution, it ensures reliable temperature management and enhanced neonatal care outcomes.

Providing premium digital services for the healthcare industry. From website design to digital marketing, we help medical businesses thrive online.

Share with friends:

The nice 2000 B Infant Radiant Warmer is a microcontroller-based neonatal warming system designed to provide a stable thermal environment for newborn infants in NICUs, delivery rooms, and neonatal care units. Featuring servo skin control, manual and APGAR modes, a quartz infrared heater, and comprehensive safety alarms, the system ensures precise temperature regulation and reliable neonatal thermal support.

Designed for continuous clinical use, the warmer incorporates a parabolic reflector for uniform heat distribution, a swivel heater module, adjustable mattress tilt, X-ray facility, and memory backup functions. Its user-friendly design, integrated monitor shelf, IV pole, and safety features make it an ideal solution for neonatal intensive care and newborn stabilization.


Key Features

  • Microcontroller-based electronics
  • Servo skin, manual, and APGAR control modes
  • High-speed microcontroller
  • No calibration required for temperature probe
  • High-intensity quartz halogen lamp
  • Quartz infrared heater
  • Uniform heat distribution
  • Parabolic reflector design
  • Heater module rotates 90° to both sides
  • Memory backup for previous settings
  • Comprehensive alarms and safety cut-offs
  • Instant warming function
  • Digital 1-inch display
  • Thermistor temperature sensor
  • Adjustable heater output from 5% to 100%
  • Over-temperature protection
  • Adjustable height mechanism
  • X-ray facility underneath the bed
  • Fixed monitor shelf
  • Adjustable IV pole
  • Lockable acrylic side panels
  • Mattress tilt ±15° on both sides
  • Rechargeable battery backup
  • Swivel castors for easy movement
  • Two-drawer storage cabinet

Applications

The nice 2000 B Infant Radiant Warmer is suitable for:

  • Neonatal Intensive Care Units (NICU)
  • Special Newborn Care Units (SNCU)
  • Delivery Rooms
  • Labor and Maternity Wards
  • Neonatal Care Units
  • Pediatric Hospitals
  • Newborn Stabilization Areas
  • Infant Observation Units
  • Postnatal Care Departments
  • Emergency Neonatal Care

The system is designed to provide effective thermal management, neonatal resuscitation support, temperature stabilization, routine newborn care, and continuous warming for premature and full-term infants requiring controlled thermal environments.

Controller

Specification Details
Electronics High Speed Micro Controller
Mode of Operation Servo Skin, Manual & Apgar
Skin Mode Control Range 32.0°C to 38.0°C
Apgar Timer Alerts at 1, 5, 10, 15 & 20 mins (selectable)
Percentage of Heater Output 5% to 100% in 5% increments
Memory Back Up Equipment restores the previous settings
Over Temperature Heater Cut Off If the skin temperature is >39°C in any skin/manual mode
Temperature Sensor (Probe) Thermistor Sensor
Accuracy of Skin Sensor ±0.1°C
Interchangeability ±0.2°C
Display Digital 1″ Display
Calibration of Skin Sensor (Probe) No need of calibration after changing new probe

Heater System

Specification Details
Heater Element Quartz Infrared Heater
Heater Module Swivel Facility
Height Adjustable ±50 mm

Power Rating

Specification Details
Power Rating 180–260V AC, 50Hz, 600W
Maximum Heater Wattage 600 Watts
Examination Light 12V, 50W Halogen Lamp/LED
Battery 12V Rechargeable Battery with backup up to 20 min for controller display

Bed & Accessories

Specification Details
Castor 3 Castors + 1 Fixed (2 with brake & 2 without brake)
Monitor Shelf 1 Nos. Fixed
X-Ray Facility Underneath the bed
Mattress Tilt ±15 deg. on both sides
Mattress Stitchless Foam with density of 21–25Kg/m and fire retardant
Mattress Size 730mm (L) × 530mm (W) × 25 (H)
Side Panels 4 side lockable Acrylic
Mattress Tray Transparent Acrylic Tray
IV Pole S.S., 2.5cm, height adjustable
Cabinet 2 draw available
Operating Noise Level <50 dBA

Controller Alarms

  • Skin temperature high
  • Skin temperature low
  • Skin probe fail
  • Over temperature
  • Heater fail
  • System fail
  • Power fail

Physical Characteristics

Specification Details
Equipment 85 cms (L) × 70 cms (W) × 185 cms (H)
Weight 50 Kgs
Maximum Load for Monitor Shelf 4.5 Kgs

Environmental

Specification Details
Operating Temperature 15.0°C to 35.0°C
Storage Temperature -20.0°C to 60.0°C
Operating Humidity 5% to 90% RH, non condensing
Storage Humidity 0% to 99% RH, non condensing
Altitude Sea level to 1.9 miles, 3 Km
Information Details
Product Name Infant Radiant Warmer
Brand Name nice Neotech
Model No nice 2000 B
Country of Origin Not Specified

Why Choose Medibyte Corporation

The nice 2000 B Infant Radiant Warmer is an advanced neonatal warming system designed to provide safe and effective thermal care for newborns in NICUs, delivery rooms, and neonatal care units. Featuring microcontroller-based temperature control, servo skin mode, quartz infrared heating, comprehensive safety alarms, and uniform heat distribution, it ensures reliable temperature management and enhanced neonatal care outcomes.